SmartMod I/O

Our new, integrated, web store is undergoing migration maintenance. Please continue to use store.heapg.com for all online transactions until further notice.
smartmodlarge
smartmod-final

Register to view pricing.

Our newest OCS I/O option, SmartMod? I/O, is now available to expand your OCS system.

Clear selection

Registration Required

Product Description

  • SmartMod I/O is a RTU/Modbus based I/O system designed to fill-out the I/O complement for applications utilizing XLe, LX, or any other OCS/RCS family Controller.
  • As many as 31 SmartMod I/O modules may be daisy chained on a single RS-485 link.
  • SmartMod I/O is DIN-rail mounted, powered from 10-30vdc, and features 2000vac optical isolation.
Part No. Description
HE359ADC120 4 channel Analog Inputs, Current (4-20mA), 1uA resolution, 2000vac isolation (ch-RS485 & ch-power)
HE359DAC107 4 channel Analog Outputs, selectable between Voltage (0-10vdc) and Current (0-20mA). 1mV or 1uA resolution. 2000vac isolation (ch-RS485 & ch-power)
HE359RTD100 4 channel RTD Inputs (Pt-100, Ni-100, Pt-1000, Ni-1000) or Resistance Inputs (0-2000ohm). 0.1 degree Celsius resolution, 2000vac isolation (ch-RS485 & ch-power)
HE359THM100 4 channel Thermocouple Inputs (Types J,K,R,S,B,E,T,N) or millivolt inputs (+/-1000mV, max). 0.1 degrees Celcius resolution, 2000vac isolation (ch-RS485 & ch-power)

Specifications

Channel: 12 channel Isolated Digital Input Module 12/24V -ve Logic, 2 channel Analog Voltage or Current Output Module 0-20mA / 0-10V, 4 channel Analog Input Module +/- 10V, 4 channel Analog Input Module +/- 20mA, 4 channel Analog Voltage or Current Output Module 0-20mA / 0-10V, 4 channel RTD Input Module, 4 channel Thermocouple Input Module, 8 channel , 4 isolated Digital Input, 4 Relay Output, 8 channel Analog Input Module +/- 10V, 8 channel Analog Input Module +/- 20mA, 8 channel Thermocouple Input Module, 8 channel Voltage Output Module 0 - 10V
4-channel-rtd-inputs-he359rtd100

SmartMod, 4 channel RTD Inputs (Pt-100, Ni-100, Pt-1000, Ni-1000) or Resistance Inputs (0-2000ohm). 0.1 degree Celsius resolution, 2000vac isolation (ch-RS485 & ch-power)

4-channel-analog-input-module-10v-he359adc107

SmartMod, 4 channel Analog Inputs, Voltage (+/-10vdc) 1mV resolution, 2000vac isolation (ch-RS485 & ch-power)

4-channel-analog-input-module-20ma-he359adc120

SmartMod, 4 channel Analog Inputs, Current (4-20mA), 1uA resolution, 2000vac isolation (ch-RS485 & ch-power)

4-channel-thermocouple-input-module-he359thm100

SmartMod, 4 channel Thermocouple Inputs (Types J,K,R,S,B,E,T,N) or millivolt inputs (+/-1000mV, max). 0.1 degrees Celcius resolution, 2000vac isolation (ch-RS485 & ch-power)

8-channel-analog-input-module-10v-he359adc207

SmartMod, 8 channel Analog Inputs, Voltage (+/-10vdc) 1mV resolution, 2000vac isolation (ch-RS-485 & ch-power)

8-channel-analog-input-module-20ma-he359adc220

SmartMod, 48 channel Analog Inputs, Current (4-20mA), 1uA resolution, 2000vac isolation (ch-RS485 & ch-power)

8-channel-thermocouple-input-module-he359thm200

SmartMod, 8 channel Thermocouple Inputs (Types J,K,R,S,B,E,T,N) or millivolt inputs (+/-1000mV, max). 0.1 degrees Celcius resolution, 2000vac isolation (ch-RS485 & ch-power)

2-channel-analog-voltage-or-current-output-module-0-20ma-0-10v-he359dac007

2 channel Analog Outputs, selectable between Voltage (0-10vdc) and Current (0-20mA). 1mV or 1uA resolution. 2000vac isolation (ch-RS485 & ch-power)

4-channel-analog-voltage-or-current-output-module-0-20ma-0-10v-he359dac107

4 channel Analog Outputs, selectable between Voltage (0-10vdc) and Current (0-20mA). 1mV or 1uA resolution. 2000vac isolation (ch-RS485 & ch-power)

8-channel-voltage-output-module-0-10v-he359dac201

8 channel Analog Outputs, Voltage (0-10vdc) 1mV resolution. 2000vac isolation (ch-RS485 & ch-power)

8-channel-4-isolated-digital-input-4-relay-output-he359diq512

SmartMod, 4 DC Inputs (12/24vdc neg logic), 4 Relay Outputs (250vac, 30vdc, 2A max). 2000vac isolation (in-RS485 & in-power)

12-channel-isolated-digital-input-module-1224v-ve-logic-he359dim610

SmartMod, 12 DC Inputs (12/24vdc, neg logic). 2000vac isolation (in-RS485 & in-power)

Documentation

Reviews

There are no reviews yet, would you like to submit yours?

Be the first to review “SmartMod I/O”